Enable or disable any of the options by pressing the button to the left of the option
(Options are selected when the button or check mark is filled in.)
- Disable Uptake
-
Alternately eliminates (displays check mark) and restores (hides check mark) the
uptake effect. When the uptake effect is disabled, Gas Man® ignores the effect
of uptake on Alveolar Ventilation (concentration effect).
- Disable Return
-
Alternately eliminates (displays check mark) and restores (hides check mark) the
return effect. When the return effect is disabled, Gas Man® ignores the effect
that the presence of agent in venous blood has on alveolar tension.
- Enable Vapor
-
Alternately adds (displays check mark) and eliminates (hides check mark) the vaporization
effect. When the vapor effect is enabled, Gas Man® adds the effect of vaporization
on fresh gas flow.
Although you can change options at any time during a simulation, making changes
while replaying a simulation will invalidate
all subsequent recorded results and adjustments. For example, rewinding a simulation
(or opening a saved simulation) and changing special options would erase it from
the revision point forward. (This will not affect the saved version.) Gas Man®
will ask you to confirm your intent whenever you modify a simulation during replay.